ABSTRACT
The coolant flow rate in conventional cooling systems in automotive engines is subject to the mechanical water pump speed, and high efficiency in terms of fuel economy and exhaust emission is not possible given this limitation. A new technology must be developed for engine cooling systems. The electronic water pump is used as a substitute for the mechanical water pump in new engine cooling systems. The new cooling system provides more flexible control of the coolant flow rate and engine temperature, which previously relied strongly on engine driving conditions such as load and speed. In this study, the feasibility of two new cooling strategies was investigated using a simulation model that was validated with temperatures measured in a diesel engine. Results revealed that active coolant control using an electronic water pump and valves substantially contributed to a reduction of coolant warm-up time during cold engine starts. Harmful emissions and fuel consumption are expected to decrease as a result of a reduction in warm-up time.
Key Words: Flowmaster, Cooling, Warm-up, Emission
Editorial Office
21 Teheran-ro 52-gil, Gangnam-gu, Seoul 06212, Korea
TEL: +82-2-564-3971   FAX: +82-2-564-3973   E-mail: manage@ksae.org
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © The Korean Society of Automotive Engineers.                 Developed in M2PI
Close layer
prev next